Skip to content

Electric and hybrid boilers for steam and hot water.

The Hybrid Boiler has electric elements and a burner in one boiler, so it makes steam or hot water from whichever energy costs least. We size it to your plant, from about 0.3 MW to over 10 MW, and larger plants run several as one. Built in Norway and run by BoilOptimizer from the first day.

Windows in the side of a black Hybrid Boiler container show the boiler shell inside, with the electric heating elements and their cabling below it

The Hybrid Boiler.
Power or fuel, without stopping the steam.

Electric elements for the cheap hours, a burner for the rest, in one boiler with one steam line to production. The burner holds the pressure while the elements step up and down, so it can deliver the fast reserves too.

The Hybrid Boiler, animation. 1 min 14 s, with sound.
Output
2,000 kW
Steam
3,000 kg/h at 100 °C feedwater
Fuel
Electricity plus natural gas, biogas, oil or bio-oil
Design pressure
Made to customer spec
Working pressure
6 to 21 bar
Voltage
3 × 690 V or 3 × 400 V
Container
12,000 × 3,500 × 3,500 mm
Standards
CE marked, PED, EN 12953 and EN 13445
Balancing markets
mFRR, aFRR, FCR-N and FCR-D
Built by
BoilerTech, Flekkefjord, Norway
Delivery
About 20 working weeks from order
Warranty
1 year

These figures are for our 2 MW container unit. Other sizes are built to your plant's demand, pressure and space.

Fits where a container fits.

The 2 MW unit is twelve metres long and three and a half wide and high. It can stand outside the boiler house and connect to the steam line you have.

The 2 MW container unit, outline in millimetres.

Sized to your plant.

From about 0.3 MW to over 10 MW per boiler, for steam or hot water. Every boiler runs under BoilOptimizer.

Hybrid Boiler in a container

Ready to stand outside. The 2 MW unit in a 12-metre container, for steam or hot water.

Several units together

More steam, or redundancy. Two or more container units side by side, run as one plant.

Hybrid Boiler on a frame

Indoors. Sized to your demand and installed in the boiler house you have.

Electric beside gas or oil

Keep the boiler you have. An electric boiler next to your gas or oil boiler. BoilOptimizer runs the two as one hybrid.

Hot water

Heat, not steam. Hot-water boilers for greenhouses, district heating and process heat, with a tank where storage pays.

Larger plants

Over 10 MW. Several boilers on one supply, designed for your site and run as one.

Buy it,
or buy the steam.

You can buy the boiler and run it with BoilOptimizer. Or we own it, install it and run it on your site, and you pay for steam or heat as a service.

In Norway, Enova supports moving steam and heat from gas or oil to electricity. We write the application with you.

Tell us about your steam or heat demand.

Demand, pressure and the boiler you have today are enough for a first answer on size and delivery.